Welcome Center showing the Pulse Settings file for Introduction to LabChart 8 The LabChart Interface LabChart has a predictable interface focused around the main LabChart window, the menu bar and toolbar at the top, and the document buttons at the bottom. The various windows for data files exist within this main window. 1 The Method of Oscillations Amplitude Measuring The Method of Oscillations Amplitude Measuring Ivan V. Kazancev, Andrey N. Lebedev, Student member, IEEE, Denis S. Abramenko, Student Member, IEEE Biysk Technological Institute (branch) of Altay State Technical University after I.I. Polzunov, Biysk, Russia information on the PC.
The Integral channel calculation provides a method of computing time-integrals with various reset methods. Integral works in real time during sampling and on pre-recorded data. The Integral dialog allows you to set up the Integral channel calculation.
1. Open the Integral dialog by selecting 'Integral...' from any Channel Calculation pop-up menu.
- Standard Integral: use all data points.
- Absolute Value: integrate absolute values of data points.
- Positive Only: use only data points whose values are greater than 0.
- Negative Only: use only data points whose values are less than 0.
4. Set up the Reset type and any additional parameters this may require:
- No Reset: integral is not reset, and the integrated signal is summed indefinitely.
- Timed Reset: integral is reset periodically, at intervals specified in the text box to the right of the reset type menu.
- Reset Each Cycle: integral is reset each time the source signal passes through zero to a positive value.
- Time Constant Decay: In this mode, input samples are summed to generate the output, as for the standard integral mode. However, each time a new sample is added the sum is multiplied by a positive constant that is a little less than 1. For a constant input voltage Vmax, the resulting sum – namely, the integral output – approaches a maximum (Vmax.?) with the time constant (tau, ?) that is entered by the user. In electronic terms, this mode approximates the behavior of a 'leaky' analog integrator, or 'RC' low pass filter. Unlike a filter, the integral multiplies the output values by the sample period in seconds and correspondingly changes the units to V.s.
- Reset By Event: use a specific event to trigger the reset (this uses the options set in the Event Options Dialogue).

- Set Scale top and Scale bottom for the calculated data in terms of the source channel units or select Auto scale to automatically generate a suitable scale for the displayed data (Recommended if performing subsequent channel calculations, on the display channel.).Choose the number of Decimal places to show in the Range/Amplitude display.
Lab Chart Reader For Mac How To Measure Amplitude Free
7. Upon clicking 'Okay', the continuous integral will appear in the channel you selected.